Power Quality Analyzers

TWOPLUS_MAIN
IN_STOCK_ICON
Available in stock

Icon

Brochure NanoVIP® TWO PLUS™ 540 kb 249 downloads

Power Quality Analyzer with MRH ™ Technology, including 4 independent channels...

NanoVIP® TWO PLUS™

Portable power quality analyzer

NanoVIP® TWO PLUS™ is a modern, compact and powerful portable Power Quality analyzer for professional use; it can be used on single-phase, two-phase, three-phase balanced networks, low and medium voltage as well as on chillers and pumping system to monitor all performance parameters.
In addition to its electrical channels, it has 4 sensor channels to read whichever type of transducer: 4..20mA, 0..1V or PT to monitor and store data of whichever system.
Thanks to the MRH™ hardware onboard, it can be connected to a QUADRA measuring network as a DGP device.
A long lasting battery and the huge logging capability of data (over 1 year) are distinguishing characteristics that make it an absolute reliable and unique professional tool.

Any energy measurement,

easiness of use

  • Light, handy, multilingual, with performance and features at the top of its class
  • LCD graphic display that allows wide flexibility in the (multilingual menu, waveforms, histograms, personalized pages, drawings, diagrams, pictures, etc.)
  • PC Software NanoStudio dedicated through which you can make advanced analysis of the data stored on uSD
  • 1 voltage measuring channel (1 phase + neutral) up to 600V CAT III, with the possibility to also measure the DC voltage, with the precision of the 0,25% + err.FS
  • 1 current input with the possibility to also measure the DC current, with the precision of the 0,25% + err.FS
  • 4 available transducer channels (4..20mA, 0..1V, PT)
  • 4 preloaded efficiency modes: chiller, pump, supply and sensors
  • Automatic verification of the correctness of the device connected to the network
  • Possibility to use flexible current probe up to 3000A or other captors with full scale set by the user
  • High capacity batteries that allow a range of campaign more than 24 hours even in the absence of mains power; no country limit when connected to the network
  • 20 alarms (generic, swells, dips and interruptions)
  • Energy Measurement in 4 time zones (rates) set

Fields of use

The NanoVIP® TWO PLUS™ is an handy tool, compact and light aimed at give a huge range of uses thanks to 4 transducers channel and MRH™ technology installed on the same device. It can be used as a Power Quality analyzer but it can also measure mechanical systems and monitor any parameter via transducer.

NanoVIP® TWO PLUS™ allows in an easy and intuitive way:

  • to control the loads, consumption and the associated network costs
  • to check in service the correct dimensioning of plants
  • to prevent the risk for overheating and insulation failures due to high harmonic content
  • to make a full Power Quality analysis
  • measure machineries realtime efficiency; preloaded modes: chiller, pump, supply and sensors
  • read and store measures collected by up to 4 transducers (4..20mA, 0..1V or PT)
  • participate to a QUADRA network as a DGP client device.
  • Identify the presence of harmonics, outages, overloads or potentially harmful voltage dips for machinery and equipment
  • Intercept fluctuations and rapid changes in current and voltage signals
  • Measure the inrush currents of motors and electrical machinery
Standard IEC61000-4-30 Class S
Dimensions 203x116x53mm
Safety 600V CAT III
Protection degree IP30
Weight 580g.
Display type LCD dot matrix with backlight
Languages English- Spanish – Italian – German – French
Communication USB to PC
Onboard memory 64kB
External memory Micro SD (4GB supplied)
Working temperature range from -10 to +55 °C
Umidity Max 95%
External power supply Wall-plug switching, input 100-240VAC ±10% 47-63Hz, changeable plug; output 7,5VDC – 12W
Battery 4 x AA MiMh 2100mAh
Autonomy >24h (wireless off)
Single phase/Double phase networks yes
Three phase 4 wires, balanced networks yes
Three phase 3 wires, balanced networks yes
Three phase 4 wires, unbalanced networks no
Three phase 3 wires, unbalanced networks no
Non electrical measures Yes, up to 4 sensors
Power analisys V, I, P, Q, S, F, PF, THD(V)%, THD(I)%, cosj, j, peaks, min, max, mid, max. demand, ecc.
Counters kWh, kVArh, kVAh (used and generated)
Waves shape V e I
Harmonics Values and spectrum up to 50°
Sags Dips, swells and net interruption
Transitory Overcurrent and overtension
Test EN 50160 yes
Starting currents yes
Measurements in DC yes
K factor Up to 25°
Alarms Video
Alarms logs 5 on video
Hourly tarifs up to 4
Consumption costs yes
Measurement campaign Unlimited, up to SD completition
Display data refres 1 sec.
Voltage (TRMS) 1 input channel 4MOhm, 2 scales
Current (TRMS) 1 input channel 10kOhm
Power Active, reactive and apparent. Single phase and total
Energy counters kWh, kvarh, kVAh
Non electrical measures Yes, up to 4 independent
Harmonics analisys Up to 50°
EN50160 analisys from 500mS up
Transitional analisys Overcurrent, overvoltage and starting currents
CE conformity 93/68/CEE (B.T. electrical materials);
89/336/CEE e 2004/108/CE (EMC)
2006/95/CE – 72/23/CEE (LVD – Low voltages);
2002/95/CE (RoHS – Dangerous materials restrictions);
2002/96/CE e 2003/108/CE (WEEE/RAEE – Wasted electrical and electronics materials).
Safety EN 61010-1
EMC EN 61326
EN 61326/A1
EN 61326/A2
EN 61326/A3
Temperature IEC 60068-2-1 (working)
IEC 60068-2-2 (storage)
Vibrations IEC 60068-2-6
Umidity IEC 60068-2-30 (umidity)
Overload IEC 60947-1
4NAN2PN NANOVIP/TWO PLUS WITHOUT CLAMP
4NANP2 NANOVIP/TWO PLUS WITH NANOFLEX CLAMP 400mm 3kA
4NAN2PA NANOVIP/TWO PLUS WITH CLAMP CT 200A/1VAC
4NAN2PB NANOVIP/TWO PLUS WITH CLAMPS 1x200A + 1x3kA
4NAN2PC NANOVIP/TWO PLUS WITH CLAMPS 1x200A + 1x5A
4NAN2PD NANOVIP/TWO PLUS WITH CLAMPS 1x200A + 1x1000A
4NAN2PE NANOVIP/TWO PLUS WITH CLAMPS 1x1000A
PART Quantity Standard/Option
NanoVIP TWO PLUS 1 Standard
Battery pack 1 Standard
Voltage cables 2 Standard
Voltage captor 1 Standard
Crocodiles 2 Standard
Magnetic voltage captors 2 Standard
PT 1000 transducers 2 Standard
Cable for 4..20mA transducers 2 Standard
Cable for 0..1V transducers 2 Standard
mSD 4Gb 1 Standard
mSD adaptor 1 Standard
External power supply + adapters 1 Standard
Bag 1 Standard
Carton box 1 Standard
Calibration certificate 1 Standard
AC Current probes 1 or more Option – According to package
DC Current clamp 1 or more Option – According to package
city-e
Not your language ?